29
Initial Installation
QUALIFIED INSTALLERS ONLY
Option 5: No Visible Discharge w/ Chase Comfort Kit (50-4175) -
If use of the CSS system is
desired/required but a visible discharge is not wanted anywhere then the Chase Comfort Kit may be used.
The Chase Comfort Kit is a blower motor housing that gets mounted on the same exterior wall as the chase
and discharges the heat outside. The Comfort Kit will always be in operation whenever the fireplace is on
and the blower speed is non-adjustable. For more details and installation specifications refer to the 50-4175
Chase Comfort Kit manual.
Figure 45: Valance Iso View
R
ecess
i
nstaLLation
These are the minimum allowable dimensions required to safely operate the appliance. Plan your entire
installation before proceeding. The maximum allowable framing depth for a recess is 3
1/2
” (90mm).
Figure 48: Recess Installation
3 1/2" (8.9cm)
Max. Framed
Recess Depth
8 x11 = 4 3/4”(12cm)
5 x 8 = 9” (22.8cm)
Min. Ceiling to Elbow
Clearance
Adjustable Framing Depth
27 1/2” [1/2” Facing] - 26" [2" Facing]
38 5/8”
(98.1cm)
11 7/8”
(30.2cm)
50 1/2”
(128.3cm)