3.4 Accessories
Uponor offers a wide variety of accessories for use with
the standard portfolio.
B
A
C
N OT E !
Some of these accessories may be included in
the system.
Item Component
Description
A
Uponor Smatrix
Sensor Outdoor
S-1XX
(outdoor sensor
S-1XX)
Outdoor sensor for use with
system without a zone setup as
Smatrix Base PRO.
B
Uponor Smatrix
Move Sensor
Supply/Return
S-152
(supply/return
sensor S-152)
Sensor that can be used as either
a supply or return sensor.
C
Uponor Smatrix
Bus cable A-145
Bus cable for use with integration
of Uponor Smatrix Base PRO
system
3.5 Functions
H
eating
Curve
The Move PRO controller use a heating curve to
calculate the supply temperature setpoint. This requires
the zone to be setup as
Stand Alone Control
or
Smatrix Base PRO
.
The heating curve for the Uponor Smatrix Move PRO
controller is shown in the diagram below. The diagram
shows the calculated supply temperature, for each
curve, at different outdoor temperatures. The controller
uses the selected curve to operate the mixing valve,
which in turn adjusts the supply temperature to the
system.
80
70
60
50
40
30
20
10
36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2
-2 -4 -6 -8 -10 -12 -14 -16 -18 -20
0
0,2
0,4
0,6
0,7
0,8
1
1,2
1,5
2
2,5
3
3,5
4
4,5
5
Supply temperature
Outdoor temperature
The choice of curve depends on a combination of
different factors, such as how well insulated the house
is, geographical location, type of heating system etc.
Example:
A poorly insulated house heated by a radiator system
requires a higher curve value than an equivalent house
with underfloor heating.
The curves in the diagram are also limited by maximum
and minimum parameters set in the system (marked in
the diagram with extra thick lines).
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
9
U P O N O R S M AT R I X M O V E P R O · I N S TA L L AT I O N A N D O P E R AT I O N M A N UA L