3. INSTALLATION
PRELIMINARY OPERATIONS
All the electrical connections and installation operations
must be done by qualified personnel according to actual
laws.
3.1 CHECK THE LOCATION OF INSTAL
LATION
Before placing the appliance, please verify the overall
measurements and the exact position of the electrical and
water connections looking at the pictures on the attached
file “TECHNICAL DATA”.
3.2 FEET ASSEMBLY
You find the feet inside the appliance. The feet must
absolutely be assembled on the oven.
Do not ever use the appliance without its feet.
Assemble the feet as showed in picture:
3.3 POSITIONING
Place the appliance respecting the safety standards in
force that you find here following described.
Place the appliance so that its back and sides can be easily
reached in order to make the electrical connections and
provide the needed service.
The appliance is not suitable for built-in installation and
side by side positioning, therefore, in case of use of more
than one oven, the appliances can not to be stacked.
It is suggested to leave a distance of 10 cm. Between the
eventual wall on the back of the oven and the chimney.
With particular reference to the ovens, all models must
be placed upon a support, for example a prover, a stand
or on the top of a table built with non-combustible mate-
rial.
Never install the appliance on the floor.
If the appliance is placed near walls, dividers, kitchen cab-
inets, decorated edges, etc., it is recommended that this
be of non combustible material.
Otherwise, they must be coated with non combustible
thermal insulating material and you must be very respect-
ful of the fire prevention standards.
3.4 REMOVE THE PROTECTIVE FILM
Carefully remove all the protective film from the exter-
nal walls of the appliance. Pay attention not to leave any
rest of glue on the sides.
If there should be any residue, please remove it with an
appropriate solvent (ex.: ethyl denatured alcohol).
4. INSTALLATION ELECTRICAL CONNEC-
TION
a
-The connection to the electrical power supply system
must be done according to the standard in force.
Use the oven at a room temperature b5 °C and
+35 °C.
Before connecting the appliance, make yourself sure that
the voltage and the frequency correspond to those stat-
ed on the data plate of the appliance. The appliance must
be placed so that the connection plug to the network can
be easily reached.
Place an omni-polar switch between the appliance and
the network. The switch must be easily accessible after
installation. The contacts of this switch must have a mini-
mum opening distance of 3 mm and the switch must have
an appropriate input. It is suggested to use a differential
magneto-thermal switch.
When the appliance is working, the power supply voltage
must not diverge from the value of the nominal voltage,
written on the technical data plate, by more than ± 10%.
The protective cover of thermal cut out should be tight so
cannot be removed without the use of a tool.
b-
The appliance must be connected to the ground line of
the network.
Moreover, the appliance must be included in an equipo-
tential system whose efficiency must be properly checked
according to the current law. This connection must be
done between the different appliances using the terminal
marked with the symbol: