4
SETTINGS AND CALIBRATIONS
67
Chapter
4
SETTINGS AND CALIBRATIONS
③
To add point(s), repeat the operation in
②
.
To correct already-created point(s), touch the left side of the
point(s) you want to correct.
All the points on the right side from the touched place are erased,
and a new point is created at the touched place.
④
After specifying all points, press
.
5.
Compare Margin
Entire waveforms are shifted by the set value. Use this when it is
required to simply shift reference waveform(s) by the set load. If
the Compare Margin is set in advance, comparison waveforms
can be created by simply inputting and saving reference
waveform(s).
Operation
Setting range (0 to 9999)
Main screen
→
Setting
→
Work Setting
→
Wave Setting
→
Compare Margin
6.
Relative Comparison
Select whether waveform comparison is made as standard or by
relative value. The comparison is invalid in continuous mode.
Operation
Setting range (Off, On)
Main screen
→
Setting
→
Work Setting
→
Wave Setting
→
Relative
7.
Reference Point of Relative Comparison
Set the reference point for making waveform comparison by
relative movement. This setting can be made only when the
setting of Relative Comparison is On.
Setting range
X-axis:
Time or displacement (Front)
(0 to 2047 × Measurement Length/2000)
Displacement (Back)
(-2047 to 0 × Measurement Length/2000)
Operation
Y-axis: (-9999 to 9999)
Main screen
→
Setting
→
Work Setting
→
Wave Setting
→
Relative Point
<In the case of one reference waveform>
<In the case of two reference waveforms>
HI limit
Reference
LO limit
Reference waveform
Reference waveform
HI limit waveform
Reference waveform;
LO limit waveform
Reference waveform
Reference waveform
Reference waveform;
waveform
waveform
waveform
+ Compare margin
- Compare margin
HI limit
LO limit
+ Compare margin
- Compare margin
Содержание TM500
Страница 1: ...01JUN2016REV 1 02 TORQUE MONITOR TM500 OPERATION MANUAL ...
Страница 9: ...Contents VIII M E M O ...
Страница 133: ...5 COMMUNICATIONS 124 Chapter 5 COMMUNICATIONS About messages Unless otherwise noted all the messages are in ASCII code ...
Страница 149: ...8 SPECIFICATIONS 140 Chapter 8 SPECIFICATIONS 8 2 Outside dimensions TM500 TORQUE MONITOR ࠉ ࠉ ࠉ Unit mm ...