4
SETTINGS AND CALIBRATIONS
58
Chapter
4
SETTINGS
AND CALIBRATIONS
- Section Start-End
(only when Change of Section is made by Setting)
Set the start point and end point of the selected section.
Setting range
(The range is the same for the start point and end point.)
Time or displacement (Front)
(0 to 2047 × Measurement Length/2000)
* Setting the start point > the end point is unacceptable.
Displacement (Back)
(-2047 to 0 × Measurement Length/2000)
Operation
* Setting the start point < the end point is unacceptable.
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Sct. Start-End
- Load HI/LO Limit
Set the range of load in which the judgment point is judged to be OK.
Setting range (-9999 to +9999: The range is the same
for the HI limit and LO limit.)
Operation
* Setting the HI limit < the LO limit is unacceptable.
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Load HI/LO Limit
- If the section start point and end point of two sections are set identically
Front reference: The start point of the next section becomes valid.
Back reference: The end point of the previous section becomes valid.
Example) If the setting is the end point (section 1) = start point (section 2) = X
Front reference: The X point falls on section 2.
Back reference: The X point falls on section 1.
- If the displacement pace is fast, sampling may not be performed in time and
no load may be held at the section start point. In that case, the load in time
for sampling near the section start point is held.
Also, when the section start point and end point are set identically, if the
displacement pace is fast, no load may be held. Set the section start point
and end point having a margin in consideration of the case where the
displacement pace is fast.
It is preferable to have a margin of the Measurement Length/2000×10 or
more.
Point
Содержание TM500
Страница 1: ...01JUN2016REV 1 02 TORQUE MONITOR TM500 OPERATION MANUAL ...
Страница 9: ...Contents VIII M E M O ...
Страница 133: ...5 COMMUNICATIONS 124 Chapter 5 COMMUNICATIONS About messages Unless otherwise noted all the messages are in ASCII code ...
Страница 149: ...8 SPECIFICATIONS 140 Chapter 8 SPECIFICATIONS 8 2 Outside dimensions TM500 TORQUE MONITOR ࠉ ࠉ ࠉ Unit mm ...
Страница 165: ......