2
INSTALLATION AND CONNECTION
21
Chapter
2
INSTALLATION AND CON
N
ECTION
2-5.
Power-on
Connect the DC power cord. (24V DC (±15%) 24W)
1.
Check that no power is applied.
2.
Remove the screws (two), and remove the
terminal block cover.
3.
Remove the screws (two) from the terminal
block.
4.
Fit the crimp contacts to the screw holes, and
fix them with the screws.
Carry out wiring from the silk-screen-printed side.
+: Red screw
-
: Black
screw
5.
Install the terminal block cover, and fix it with the screws (two).
2-6.
Protective Ground Connection
The grounding terminal is for prevention of electric shocks.
Use an approx. 0.75mm
2
thick wire, and be sure to ground.
1.
Make sure that no power is applied.
2.
Remove the screws(M4) at the protective
ground.
3.
Align the solderless terminals(M4) with the
screw holes, and then tighten the screws.
CAUTION
●
Connect with no power applied because it may cause an electric shock.
●
Since the TM500 has no power switch, install a breaker.
●
Be sure to ground the protective ground terminal to prevent electric shocks.
Do not use other screws than that attached to the main body.
Within 6mm
Red screw
Black screw
DC IN
+
-
Be aware that the voltage drops depending on the wire thickness and length.
Also, never input an AC power source. Doing so will cause a failure.
Attention
DC IN
+
-
M4
Protective ground
Содержание TM500
Страница 1: ...01JUN2016REV 1 02 TORQUE MONITOR TM500 OPERATION MANUAL ...
Страница 9: ...Contents VIII M E M O ...
Страница 133: ...5 COMMUNICATIONS 124 Chapter 5 COMMUNICATIONS About messages Unless otherwise noted all the messages are in ASCII code ...
Страница 149: ...8 SPECIFICATIONS 140 Chapter 8 SPECIFICATIONS 8 2 Outside dimensions TM500 TORQUE MONITOR ࠉ ࠉ ࠉ Unit mm ...
Страница 165: ......