4
SETTINGS AND CALIBRATIONS
54
Chapter
4
SETTINGS
AND CALIBRATIONS
If Sample is selected to Hold, the setting items of the right screen are
displayed.
- Detection Start Load
Set the load to judge displacement while regarding a load as a
trigger.
It is convenient for judging displacement with respect to the initial
torque.
Press
for Sample Hold of the section start point.
Operation
Setting range (-9999 to 9999)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Use Hold
→
Sample
→
Start Load
If Relative Minimum or Relative Maximum is selected to Hold, the
setting items of the right screen are displayed.
- Detection Start Load
Set the load to start the detection of Relative Maximum (Relative
Minimum).
If you do not use Detection Start Load, press
.
Operation
Setting range (-9999 to 9999)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Use Hold
→
Rel. Max. (or Rel. Min.)
→
Start Load
- Detection Load Difference
Set the load difference of Relative Maximum or Relative Minimum.
Select with the Up key for the Relative Maximum, and with the
Down key for the Relative Minimum.
Operation
Setting range (1 to 19998)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Use Hold
→
Rel. Max. (or Rel. Min.)
→
Load Difference
Содержание TM500
Страница 1: ...01JUN2016REV 1 02 TORQUE MONITOR TM500 OPERATION MANUAL ...
Страница 9: ...Contents VIII M E M O ...
Страница 133: ...5 COMMUNICATIONS 124 Chapter 5 COMMUNICATIONS About messages Unless otherwise noted all the messages are in ASCII code ...
Страница 149: ...8 SPECIFICATIONS 140 Chapter 8 SPECIFICATIONS 8 2 Outside dimensions TM500 TORQUE MONITOR ࠉ ࠉ ࠉ Unit mm ...
Страница 165: ......