14.RS-232C INTERFACE
49
- Command
- Please refer to "21 SETTING ITEM LIST" on page 65 for command No. of parame-
ter read(write) and parameter digit.
- When the digit is less than five digits, it treats by "0".
Example) Comparison prohibition time read
Host
F600AT
W
3
W
3
2
0
0
0
9
9
CR
2
Terminator
9
Parameter
Sign
Command No.
It sends it back by 0.
SPAN CALIBRATION
NET SELECTION
DIGITAL ZERO RESET
EQUIV. CALIBRATION
ZERO CALIBRATION
GROSS SELECTION
TARE SUBTRACTION
DIGITAL ZERO
PRINT INSTRUCTION
equipment connected to SI/F as desired.
A
C
CR
C
C
CR
E
C
CR
G
C
CR
I
C
CR
B
C
CR
D
C
CR
F
C
CR
H
C
CR
L
C
CR
TARE RESET
* Refer to below.
* A print instruction is given to the
How to use the CL command (equivalent input calibration execution)
1) Correct values should previously be set to “equivalent input calibration” and “weight value”.
Therefore, check the rated output and rated capacity of the load cell as in the case of
equivalent input calibration by the touch panel.
Example) It is assumed that the rated output and the rated capacity of the load cell are
2.000mV/V and 100.00kg, respectively.
2) Set the rated input by using the command W83 (equivalent input calibration).
Example) For 100.00kg (assuming that the decimal point is positioned as 0.00), input as
follows:
3) Set the rated capacity by using the command W84 (weight value).
Example) For 100.00kg (assuming that the decimal point is positioned as 0.00), input as
follows:
4) Give the equivalent input calibration execution command (CL).
This allows slope calculation from the currently registered “weight value” and
“equivalent input calibration” value.
W 8
3
0
0
2
0
0
0 CR LF
Input 2.000mV/V as a value of 2000 with no decimal point.
W 8
4
0
1
0
0
0
0 CR LF
Input 100.00kg as a value of 10000 with no decimal point.