15.BCD DATA OUTPUT (OPTION)
51
15. BCD DATA OUTPUT (OPTION)
The BCD data output is an interface to extract the indicated value of the F600AT as BCD data. This
interface is convenient to process controls, totals, records, etc., by connecting the F600AT to a
computer, process controller, sequencer or the like.
The I/O and internal circuits are electrically insulated by photocoupler.
15-1. Connector Pin Assignment
32 pin
Compatible connector: FCN-361J032-AU (manufactured by FUJITSU COMPONENT or equivalent)
Connector cover:
FCN-360C032-B (manufactured by FUJITSU COMPONENT or equivalent)
(Connector & cover optional type: CN51)
Special-purpose
connector
No.
Signal
No.
Signal
A1
*
COM
B1
*
COM
A2
OUT
1
B2
OUT
1000
A3
OUT
2
B3
OUT
2000
A4
OUT
4
B4
OUT
4000
A5
OUT
8
B5
OUT
8000
A6
OUT
10
B6
OUT
10000
A7
OUT
20
B7
OUT
20000
A8
OUT
40
B8
OUT
40000
A9
OUT
80
B9
OUT
80000
A10
OUT
100
B10
OUT
Minus (Polarity)
A11
OUT
200
B11
OUT
OVER
A12
OUT
400
B12
OUT
STAB
A13
OUT
800
B13
OUT
STROBE
A14
IN
BCD Data Hold
B14
IN
Logic Switching
A15
IN
NC
B15
IN
NC
A16
-
B16
-