11.TIMING CHART
41
11-3-2. Sequence when the adjust feeding is ON
The completion signal output timing depends on the COMPLETE SIG.OUT setting under
COMPARISON.
The overweight/underweight comparison timing is such that the OVER/UNDER COMP. setting under
COMPARISON is ignored, but comparisons are made when the completion output is ON, and the
weight value is held.
11-3-3. Sequence with no judgment
When the number of JUDGING TIMES under SEQUENCE MODE is 00, overweight/underweight
judgment is not made.
The END signal output timing is such that the COMPLETE SIG.OUT setting is ignored, but it is output
at the OFF edge (ON
→
OFF) of the final weight signal (SP3 signal).
Completion output time
Adjust feeding time
Judging time
Comparison inhibiting time
Judgment output
END output
SP1 output
ON
ON
ON
ON
ON
Hold
OFF
t2
t3
t4
t1
t1
t2
START input
STOP input
SP2 output
SP3 output
t1: Comparison inhibiting time
COMP.INH.TIME under
COMPARISON
t2: Judging time
JUDGING TIME under
COMPARISON
t3: Completion output time
COMPLETE OUT T. unde
COMPARISON
t4: Adjust feeding time
ADJ.FEEDING TIME
under SEQUENCE MODE
(OVER)
SP1 output
SP2 output
SP3 output
END output
Comparison inhibiting time
Completion output time
ON
OFF
ON
ON
ON
ON
t3
t1
t1
t1: Comparison inhibiting time
COMP.INH.TIME under
COMPARISON
t3: Completion output time
COMPLETE OUT T. under
COMPARISON
START input
STOP input