6.HOW TO SET THE FUNCTIONS
27
■
For final discharge – over weight/under weight comparison
(when “DIS.-O/U” is selected by comp mode sel.)
When the net
≧
final weight – SP1, the status display “SP1” lights, and the signal output “HH/SP1”
turns ON.
*2
When the net
≧
final weight – SP2, the status display “SP2” lights, and the signal output “GO/SP2
turns ON.
*2
When the net
≧
final weight – CPS, the status display “SP3” lights, and the signal output “LL/SP3”
turns ON.
*2
When the net
>
final over weight, the status display “OVER” lights, and the signal output
“HI/OVER” turns ON.
When the net
<
final weight – under weight, the status display “UNDER” lights, and the signal output
“LO/UNDER” turns ON.
The fall regulation value “AFFC” relates to the automatic fall compensating function.
*2: Output in the simple comparison mode. For the sequence mode, refer to page 40.
■
For final discharge – HI/LO limit comparison
(when “DIS.-H/L” is selected by comp mode sel.)
When the net
≧
final weight – SP1, the status display “SP1” lights, and the signal output “HH/SP1”
turns ON.
When the net
≧
final weight – SP2, the status display “SP2” lights, and the signal output “GO/SP2 turns
ON.
When the net
≧
final weight – CPS, the status display “SP3” lights, and the signal output “LL/SP3”
turns ON.
When the weight value
>
HI limit, the signal output “HI/OVER” turns ON.
When the weight value
<
LO limit, the signal output “LO/UNDER” turns ON.
Setting item
Input range
[FINAL]
00000 to 99999
[SP1]
00000 to 99999
[SP2]
00000 to 99999
[CPS]
0000 to 9999
[AFFC]
00000 to 99999
[OVER]
000 to 999
[UNDER]
000 to 999
Setting item
Input range
[FINAL]
00000 to 99999
[SP1]
00000 to 99999
[SP2]
00000 to 99999
[CPS]
0000 to 9999
[AFFC]
00000 to 99999
[HI]
±
00000 to
±
99999
[LO]
±
00000 to
±
99999