6.HOW TO SET THE FUNCTIONS
26
6. HOW TO SET THE FUNCTIONS
□
Code No. selection
Press
the
/
key
on the each code setting screen, and specify the code No. you want to set.
Setting range:
[
0 to 7
]
[
ALL
]
When each item is set with the code No. specified as “ALL,” the same set value enters into all of code
0 to 7 on the set item. This function is convenient when there is any item you want to set all code in
common.
□
Code copy
Code can be copied. Press
the
key
on the each code setting
screen. Set source and copy.
Setting range:
Source: (0 to 7)
Copy:
(0 to 7)
■
For HI/LO limit comparison
(when “HI-LO comp” is selected by comp mode sel.)
When the weight value
>
HI-HI limit, the status display “HH” lights, and the signal output “HH/SP1”
turns ON.
When the weight value
>
HI limit, the status display “HI” lights, and the signal output “HI/OVER”
turns ON.
*1
When the LO limit
<
weight value
<
HI limit, the status display “GO” lights, and the signal output
“GO/SP2” turns ON.
*1
When the weight value
<
LO limit, the status display “LO” lights, and the signal output “LO/
UNDER” turns ON.
*1
When the weight value
<
LO-LO limit, the status display “LL” lights, and the signal output “LL/SP3”
turns ON.
Select the weight value from net or gross.
*1: Output when the HI/LO limit comparison output is in the “NORMAL” mode.
For the “COMPARATOR” mode, refer to page 31.
COPY
Setting item
Input range
[HH]
±
00000 to
±
99999
[HI]
±
00000 to
±
99999
[LO]
±
00000 to
±
99999
[LL]
±
00000 to
±
99999
Содержание F600AT
Страница 1: ...F600AT 01MAY2015REV 3 01 WEIGHING CONTROLLER OPERATION MANUAL...