5.COMPARISON SETTING
24
■
Discharge control mode
Valid in the discharge mode. Select FEEDING or DISCHARGE.
By selecting EXTERNAL, switching is carried out between FEEDING and DISCHARGE according to
the level of the input terminal “F/D.”
Alternatives:
[
FEEDING
]
[
DISCHARGE
]
[
EXTERNAL
]
■
Completion signal output mode
Valid in the discharge mode. Select the method of outputting the completion signal.
Alternatives:
[
JUDGING TIME
]
[
JUD. or STABLE
]
[
JUD. & STABLE
]
Explanation of each alternative
JUDGING TIME
The signal is ON only for the duration of the completion output time after the
judging time has elapsed.
JUD. or STABLE
The signal is ON only for the duration of the completion output time after the
weight value has become stable or the judging time has elapsed.
JUD. + STABLE
The signal is ON only for the duration of the completion output time after the
weight value has become stable and the judging time has elapsed.
■
Overweight/underweight comparison mode
Valid when “DIS.-O/U” is selected by COMP MODE SEL.
Select the method of overweight/underweight comparison.
Alternatives:
[
REGULARLY
]
[
COMP.SIG.
]
[
EXT.IN
]
[
COMP.SIG&H
]
Explanation of each alternative
[
REGULARLY
]
Comparisons are made regularly.
[
COMP.SIG.
]
Comparisons are made when the completion signal is ON.
[
EXT.IN
]
Comparisons are made when the external judgment input is ON.
[
COMP.SIG&H
]
Comparisons are made when the completion signal is ON, and the weight
value is held.
*
If [EXT.IN] is selected, comparisons are made according to the level of input terminal “HOLD/JUDGE”.
*
In the sequence mode (page 40), this setting is ignored, but comparisons are made when the
completion signal is ON, and the weight value is held.
OFF
FEEDING
DISCHARGE
Indeterminate interval (within 50msec.)
F/D (B10)
ON
OFF
Comparison inhibition
Comparison
Indeterminate interval (within 50msec.)
HOLD/JUDGE (B9)
ON
Содержание F600AT
Страница 1: ...F600AT 01MAY2015REV 3 01 WEIGHING CONTROLLER OPERATION MANUAL...
Страница 81: ......