Page 25 of 36
REV D1
Sprite Installation and Operator’s Manual
12.3 Alerts and LCD Messages
An alert occurs when the Unit detects a condition requiring user intervention such as an empty stock bin, etc. Alerts are
indicated by a buzzer sounding and an illuminated LED indicator. A corresponding message is displayed on the control
panel LCD. The amber stock LED may also light if the alert condition was caused by the Unit running out of stock.
An alert can be either soft or hard. Soft alerts require only that the condition (such as out of stock) be corrected to clear the
alert. Hard alerts require that the
RESET/EXIT
push-button be pressed after the condition (such as a stock jam) is
corrected.
Basic LCD Alert Messages
Refer to following table for a list of the messages displayed, their description, and the appropriate corrective action:
LCD
Messages
Description
Corrective Action
(ALERT CLEAR)
Communications error (primarily related
to serial communications with the host).
Typical message sequence when the Unit
detects that the incoming data does not match
its communication parameters such as baud
rate, parity, or data/stop bit size.
No floppy diskette detected in disk drive.
Insert Unimark Application System Software
floppy diskette in disk drive.
Ensure diskette is fully inserted in disk drive.
Font
files
unreadable, missing, or
corrupted.
Insert backup floppy diskette in disk drive.
Ensure diskette is fully inserted in disk drive.
Application
flash
unreadable
or
corrupted.
Controller board is most likely unusable.
Contact Unimark Service.
Setup files unreadable, missing, or
corrupted.
These are scrolling messages; wait for the
entire message for complete instructions.
Insert backup floppy diskette in disk drive.
Ensure diskette is fully inserted in disk drive.
Setup files could be replaced on floppy, or
unit may automatically recreate them if
possible.
F l o p p y
F a i l e d
N o F o n t s
F o u n d
N o A p p
F o u n d
N o S e t u p
F o u n d
O n l i n e
C o m m E r r