![Uniclass Prima IP 16 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/uniclass/prima-ip-16/prima-ip-16_user-manual_839425067.webp)
Prima IP KVM Switch User Guide R1.4
Enable Alarm: Check this option to enable
Prima IP
to respond to specific alarm triggering
events.
Restart Computer: Check this option to restart computer upon specific alarm triggering events.
Send an e-mail: Check this option to send an alert e-mail upon specific alarm triggering events.
Send an SNMP Trap: Check this option to send an SNMP trap message upon specific alarm
triggering events.
If you uncheck the
Enable Alarm
option, you won’t trigger any alarm types even if you have checked
the
Restart Computer
and
Send an E-mail
option.
For the MIB structure of Prima IP, please refer to the followings: (you can also find it in the form of a
file,
P ima IP-MIB.txt
, on the Prima IP Support CD-ROM).
r
Prima IP-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB;
prosum OBJECT IDENTIFIER ::= { enterprises 997 }
products
OBJECT IDENTIFIER ::= { prosum 5 }
kvmIP
OBJECT IDENTIFIER ::= { products 4 }
Prima IP
OBJECT IDENTIFIER ::= { kvmIP 1 }
-- trap numbers can be under
here
trapInfo
OBJECT IDENTIFIER ::= { Prima IP 1 } -- typical root for the trap
variables
-- Prima IP Object
alertMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..256))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The text of the alert message."
::= { trapInfo 1 }
Prima IPName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..256))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Name of the Prima IP unit that generated the trap."
::= { trapInfo 2 }
computerNumber OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"the number of the computer that originated the trap."
::= { trapInfo 3 }
computerName OBJECT-TYPE
- -
63