DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-64-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0xC7
READ
SETPOINT
NORMAL
1byte
Responds within the tolerance range of 10% or more
of the rating for the setpoint.
2%
~
50%
→
2
~
50
2
:
0x02
50
:
0x32
0x56
0xC8
READ
SETPOINT
FAIL
2byte
Responds to the time until transition to FAIL if
SETPOINT is not output within the set time.
0.0s
~
60.0s
→
0
~
600
600
:
0x0258
0xC8
0xC9
Option C
READ
LEVEL
HI RES
2byte
Responds with the output command value.
Responds with a resolution higher than READ
LEVEL (0x91).
Only two units can be used at a maximum in system
connection.
The setting in each control mode is as follows:
For Current, enter a value 10times larger than the
set value.
Power
0, 20
~
20000 (0x4E20)
20000W×1unit
0, 40
~
40000 (0x9C40)
20000W×2units
Voltage
0, 50
~
800 (0x0320)
0, 50
~
1000 (0x03E8)
HV Spec.
Current
0, 5
~
500 (0x01F4)
50.0A×1unit
0, 10
~
1000
(0x03E8)
50.0A×2units
0x58
0xCA
READ
POWER
HI RES
2byte
Responds with the output value of the electric
power.
The value depends on the P/S configuration.
Responds with a resolution higher than READ
POWER (0x92).
Only two units can be used at a maximum in system
connection.
0W
~
40000W
→
0
~
40000
40000
:
0x9C40
0xCB
READ
MONITOR
HI RES
7byte
Responds collectively with each value of the electric
power, voltage, current, and condition (Status).
Responds with a resolution higher than READ
MONITOR (0x98).
Electric power response command
:
0xCA
Voltage response command:
0x93
Current response command:
0x94
Condition response command:
0x90
The same data as the above-mentioned ones are
responded.
Responds with data of seven bytes in total.
Responds with the electric power, voltage, and
current each of two bytes.
Electric power
→ Voltage → Current → Condition
(Status)
The data are sent from the power supply in the
above order.
Only two units can be used at a maximum in system
connection.