![Ulvac DC-10-D Скачать руководство пользователя страница 68](http://html2.mh-extra.com/html/ulvac/dc-10-d/dc-10-d_operation-manual_4836559068.webp)
DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-59-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x87
READ
FAIL UNIT
NUMBER
2byte
If FAIL occurs in a P/S-connected system, this
responds with the unit with FAIL.
The corresponding bit in the P/S system is set to
ON.
If FAIL occurs in multiple units, the corresponding
bits are all set to ON.
Unit1
:
0x0001 Unit7
:
0x0040
Unit2
:
0x0002 Unit8
:
0x0080
Unit3
:
0x0004 Unit9
:
0x0100
Unit4
:
0x0008 Unit10
:
0x0200
Unit5
:
0x0010 Unit11
:
0x0400
Unit6
:
0x0020 Unit12
:
0x0800
Example:
Responds with 0x0031 in the event of FAIL in Unit1,
Unit5, and Unit6.
0x88
READ
FAIL
1byte
0x00 -> P1
0x01 -> S1
0x02 -> S2
・
・
0x0B ->S11
4byte
Responds with details on FAIL that has occurred.
By specifying a unit to query, the bit corresponding
to FAIL is set to ON.
If FAIL occurs in multiple units, the corresponding
bits are all set to ON.
For error codes and details on the errors, refer to
Table 4-11 in [4-14 Display of ERROR code on front
panel].
---
0x00000000
No errors
F10*
0x00000001
FAIL SUB UNIT
F11*
0x00001000
FAIL OTHER
F12*
0x00000400
FAIL PROCESS
F13*
0x00000004
FAIL COMM
F14*
0x00000800
FAIL HARD
F15*
0x00100000
FAIL DIAG
F16*
0x00040000
FAIL CONNECT
F17*
0x00000200
FAIL FAN
F18*
0x00000100
FAIL TEMP
F19*
0x00004000
FAIL EMG STOP
F20*
0x00400000
FAIL SETP LIM
F21*
0x00800000
FAIL SETP IGN
F22*
0x02000000
FAIL SETP SHT
F23*
0x01000000
FAIL SETP OTH
F24*
0x00000040
FAIL INPUT
F25*
0x00000080
FAIL OUTPUT
F26*
0x04000000
FAIL ARC ABSO
F27*
0x00200000
FAIL ARC RATE
Example:
Responds with 0x00040800 in the event of FAIL in
Primary F161 and Secondary F142.
0x90
READ
STATUS
1byte
Responds with the condition (Status).
The condition can be determined from the following
bits:
0x01: In the process of DC ON
0x02: READY signal output
0x04: OUTPUT signal output
0x08: SETPOINT signal output
0x10: INTER LOCK release
0x40: In the event of WARNING
0x80: In the event of FAIL
0x10
or
0x11