DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
4. Description of Functions
-27-
Table 4-9
:
Each parameter (SET layer)
Layer 1
Layer 2
Layer 3
Layer 4
MENU
No.
Description
Option
SET
LIMT
IGNV
A15
Setting of ignition voltage limit.
The output is limited when the output voltage reaches the set value at
ignition.
When it is set to a value lower than Menu No. A16, the voltage
limit uses this set value with the highest priority even after the
completion of ignition operation.
VOLT
A16
Output voltage limit:
The output is limited when the output voltage reaches the set value
after the completion of ignition operation.
CRNT
A17
Output current limit:
The output is limited when the output current reaches the set value.
POW
A18
Output power limit:
The output is limited when the output power reaches the set value.
CLR
WARN
A19
The WARNING log is cleared when changed to YES and confirmed.
FAIL
A20
The FAIL log is cleared when changed to YES and confirmed.
ARC
A21
The ARC log is cleared when changed to YES and confirmed.
INIT
A22
All parameters are reset to their defaults when changed to YES and
confirmed.
SET
CONT
A23
The operation mode can be changed. For details, see Section 4-2.
MODE
A24
The output mode can be set to any one of constant power, constant
current, or constant voltage.
UNIT
A25
Set this parameter when using multiple Units as a system.
Changing the setting value initializes the limit setting value.
STEP
NRML
A26
The setting of thresholds for outputting SETPOINT signals in the
range of 10% to 100% of the rating. When the monitor values are
within the range of their thresholds with respect to the command
values, SETPOINT signals are output.
LOW
A58
The setting of thresholds for outputting SETPOINT signals in the
range of 1% to 10% of the rating. When the monitor values are within
the range of their thresholds with respect to the command values,
SETPOINT signals are output.
FAIL
A27
Setting of FAIL SETP.
FAIL processing is performed when the SETPOINT signal is not
output within the set time.
If set to 0, FAIL processing is disabled.
CSTM
LEVL
A43
The setting of the operation rights for command values in the CSTM
operation mode.
ON
A44
The setting of the operation rights for ON in the CSTM operation
mode.
MODE
A45
The setting of the operation rights for MODE in the CSTM operation
mode.
RST
A46
The setting of the operation rights for RESET in the CSTM operation
mode.
PARM
A47
The setting of the operation rights for selection between parameters
A and B in the CSTM operation mode.
PRE
A53
Select to use PRESET settings.
Set this when using our separate
unit.
COMM
BPS
A28
The setting of SERIAL communication rate.
You can select any one of 9600/19200/38400/57600/115200 bps.
TERM
A29
The setting for use of SERIAL communication terminating resistor.
YES: The terminating resistor is used.
NO: The terminating resistor is unused.
ADRS
A30
The setting of SERIAL communication address.
FBUS
A49
The setting of EtherCAT communication.
E
RAMP
NRML
A32
The RAMP setting for electric discharge.
The RAMP time can be set for the rise of the output in electric
discharge.
IGNI
A31
The RAMP setting for ignition operation.
The RAMP time can be set for the ignition voltage before electric
discharge.
R
ALWY
A56
The RAMP time can be set for the output follow-up operation during
the change of command values.
R