DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-56-
Write Commands
Transmission data
Response data
Read
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x5F
SET
ARC
SIGNAL
TIME
1byte
Used to set the time for the micro-arc signal for
USER1 PORT.
100us
:
0x00
1ms
:
0x01
10ms
:
0x02
100ms
:
0x03
1byte
STATUS
0xD7
0x60
SET
PARAM
PRESET
1byte
Used to set PARAM PRESET.
Two consecutive submissions will be accepted.
NONE
:
0x00
PRESET 1
:
0x01
1byte
STATUS
0xD8
0x61
SET
COMM
TERM
1byte
Used to set COMM TERM (RS-485 terminating
resistor NO/YES)
NO
:
0x00
YES
:
0x01
1byte
STATUS
0xD9
0x62
Option R
SET
RAMP
ALWAYS
2byte
Used to set the rising time of regular output
operation.
It can be set in steps of 1 ms.
Disabled when set to 0 ms.
0, 10ms
~
10000ms
→
0, 10
~
10000
10000
:
0x2710
1byte
STATUS
0xDA
0x63
SET
CONTROL
MODE
CUSTOM
LEVEL
1byte
Used to set the right to make the LEVEL setting.
This can be set when CONTROL MODE is
[CSTM].
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
1byte
STATUS
0xDB
0x64
SET
CONTROL
MODE
CUSTOM
ONOFF
1byte
Used to set the right to make the DC ON/OFF
setting.
This can be set when CONTROL MODE is
[CSTM].
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
1byte
STATUS
0xDC
0x65
SET
CONTROL
MODE
CUSTOM
OUTPUT
MODE
1byte
Used to set the right to make the OUTPUT MODE
setting.
This can be set when CONTROL MODE is
[CSTM].
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
1byte
STATUS
0xDD
0x66
SET
CONTROL
MODE
CUSTOM
RESET
1byte
Used to set the right to make the FAIL RESET
setting.
This can be set when CONTROL MODE is
[CSTM].
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
ANY
:
0x03
1byte
STATUS
0xDE