DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-57-
Write Commands
Transmission data
Response data
Read
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x67
SET
CONTROL
MODE
CUSTOM
PARAMETER
1byte
Used to set the right to make the setting for
PARAMETER switching.
This can be set when CONTROL MODE is
[CSTM].
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
1byte
STATUS
0xDF
0x68
SET
SETPOINT
LOW
1byte
Sets the allowable range of setpoints below
10%
of the rating.
It can be set in steps of 1%.
2%
~
50%
→
2
~
50
2
:
0x02
50
:
0x32
1byte
STATUS
0xE0
0x69
SET
FAIL ARC
ABSO
2byte
Detected to FAIL when HARC is detected a set
number of times.
It can be set in steps of 1 time.
0 to 50000 times
→
0 to 50000
50000
:
0xC350
1byte
STATUS
0xE1
0x6A
SET
FAIL
ARC RATE
CNT
2byte
Detected to FAIL when HARC is detected a set
number of times within a set time.
It can be set in steps of 1 time.
0 to 50000 times
→
0 to 50000
50000
:
0xC350
1byte
STATUS
0xE2
0x6B
SET
FAIL
ARC RATE
TIME
2byte
ARC RATE CNT setting time.
It can be set in steps of 0.1 s.
0.1s
~
100.0s
→
1
~
1000
1
:
0x0001
1000
:
0x03E8
1byte
STATUS
0xE3
0x6C
SET
ARC LEVEL
CURRENT
2byte
Use to set the arc detection level by current.
It can be set in steps of 1A.
*
When P/S connection is made, it is the current
value at the time of synthesis.
10A
~
1080A
→
10
~
1080
10
:
0x000A
1080
:
0x0438
1byte
STATUS
0xAC