10
30A215-Mar2008
11
30A215-Mar2008
F. OPERATING CONTROLS:
The fryer is equipped with an Ultrastat 25 Cooking Computer as shown below. Operating instructions for the Ultrastat 25 Cooking
Computer (PN 30A051) will be provided with the fryer. Operating controls on the fryer include the Ultrastat 25 Cooking Computer
and the RED Heating Indicator Lamp. These controls are mounted on the Controller door; and the temperature probe , main drain
valve, and other fryer controls are located behind the access door. These controls were identified in the illustrations shown on
the previous page.
G. AUTOMATIC SAFETY FEATURES:
1. High limit thermostat to shut off gas to the main burners by opening a solenoid-actuated safety valve in the combination gas
control valve.
2. Combination gas control valve which includes a built-in pressure regulator and manual valve.
3. Air pressure switch to open the 24 volt electrical circuit to the combination gas control valve, which turns gas to the fryer OFF
if a Blower Motor becomes inoperable.
4. Sensing circuit within the spark ignitor module to which turns gas to the fryer OFF if a burner FLAME OUT occurs.
5. A Current Sensor and Air Pressure switch which, combined, provide an Air Proofing System for the fryer.
6. A Drain Valve Safety Switch that will turn the gas to the fryer OFF each time the drain valve is Opened.
H. RATING PLATE:
The Rating Plate is located on the inside of the Service Access door and contains the following information: the model and serial
numbers, BTU/HR input rating of the burners, gas manifold pressure in inches W.C. , minimum inlet gas required, orifice size,
and gas type. This data is essential for proper identification when communicating with ULTRAFRYER SYSTEMS or requesting
special parts or information.
DANGER
THE FRYER MUST BE CONNECTED ONLY TO THE TYPE OF GAS IDENTIFIED ON THIS RATING PLATE!