background image

1

30A215-Mar2008

WARNING!! 

TO ASSURE PRODUCING A QUALITY PRODUCT WHILE PROLONGING THE LIFE

 

 

EXPECTANCY OF THE FRYER, ENSURE FILTERING, BOIL-OUT, AND CLEANING 

 

 

INSTRUCTIONS ARE STRICTLY FOLLOWED.

Model PD14” (356mm)

Dual Rated Gas Fryer

Operation Instructions

Ultrafryer Systems

302 Spencer Lane

P.O. Box 5369

San Antonio, TX 78201

Local:  (210) 731-5000

Toll-Free:  (800) 525-8130

Fax:  (210) 731-5099

Web:  www.ultrafryer.com

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Содержание PD14

Страница 1: ...NG INSTRUCTIONS ARE STRICTLY FOLLOWED Model PD14 356mm Dual Rated Gas Fryer Operation Instructions Ultrafryer Systems 302 Spencer Lane P O Box 5369 San Antonio TX 78201 Local 210 731 5000 Toll Free 80...

Страница 2: ...led by professional personnel as specified Installation maintenance and repairs should be performed by your ULTRAFRYER FACTORY AUTHORIZED SERVICE CENTER DANGER Do not store or use gasoline or other fl...

Страница 3: ...ilation 13 RECEIVING INSTALLING Unpacking 15 Installing 15 Leveling 15 Gas Connection 16 Electrical Connection 16 Ultrastat 25 Cooking Computer 17 INITIAL STARTUP Cleaning 19 Startup 19 Lighting Instr...

Страница 4: ...rastat 25 Cooking Computer Programming 31 Shortening Installation 32 Start Up And Cooking 34 TECHNICAL ASSISTANCE ORDERING INFORMATION Technical Assistance 36 Ordering Information 36 RECOMMENDED SPARE...

Страница 5: ...5 30A215 Mar2008 GENERAL INFORMATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 6: ...rafryer Systems will notify an authorized service agent to make repairs during normal hours or after hours Any parts that need to be shipped back to Ultrafryer Systems will be shipped back prepaid by...

Страница 7: ...yer is burns from hot shortening In order to prevent serious burns good housekeeping habits are required The floor in front of and the area around the fryer should be kept clean and dry Whenever anyth...

Страница 8: ...30 FT3 hr 0 84 M3 hr 42 FT3 hr 1 2 M3 hr 38 FT3 hr 1 0 M3 hr Shipping Cube 13 32 FT3 36 M3 Shipping Weight 185 lbs 84 kgs Power Input 120 Volt 36 Amp 60 Hz 1 FT3 HR M3 HR VALUES May vary due to heati...

Страница 9: ...9 30A215 Mar2008 MODEL 14 PD GAS FRYER E OPERATING CONTROLS LOCATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 10: ...4 volt electrical circuit to the combination gas control valve which turns gas to the fryer OFF if a Blower Motor becomes inoperable 4 Sensing circuit within the spark ignitor module to which turns ga...

Страница 11: ...To determine the inlet gas line diameter for the distance between the fryer and main gas regulator locate the FT3 HR M3 HR of gas required for the fryer and pipe length and read the pipe diameter on t...

Страница 12: ...12 30A215 Mar2008 PRE INSTALLATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 13: ...70 latest edition In Canada electrical installation must be in accordance with the current Canadian Electrical Code CSA C22 1 and CSA C22 2 as applicable 4 Other applicable nationally recognized inst...

Страница 14: ...14 30A215 Mar2008 RECEIVING AND INSTALLING PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 15: ...asters and insert the appropri ate number of shim plates between leg and caster plates then retighten the caster bolts 2 If the floor is smooth and level adjust to the high corner and measure with a s...

Страница 16: ...following OUTLET gas pressure PRIOR to start up of a fryer NATURAL GAS FRYERS 4 102mm W C BUTANE PROPANE FRYERS 10 254mm W C 5 Rigid connections Check any installer supplied intake pipe s visually and...

Страница 17: ...display board the Ultrastat 25 Cooking Computer has been customized for Ultrafryer Systems applications by the addition of up to 10 stage cooking profiles for each of the 8 product keys exit melt fea...

Страница 18: ...18 30A215 Mar2008 INITIAL STARTUP PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 19: ...LT MODE WARNING DO NOT USE A MATCH OR CANDLE TO LIGHT A FRYER EVER D SEQUENCE OF IGNITION When the lighting instruction steps are performed in the sequence listed above the following will occur 1 Blow...

Страница 20: ...TION RESPONSE 1 Ensure the drain valve lever is in the closed position and that water is at the proper level CAUTION PRIOR TO PROCEEDING TO STEP 2 VISUALLY CHECK THAT THE HEAT EXCHANGER TUBES ARE COVE...

Страница 21: ...21 30A215 Mar2008 PREVENTIVE MAINTENANCE AND TROUBLESHOOTING PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 22: ...and allow them to dry overnight WEEKLY Drain Valve Handle Temperature Sensing Probes Agitator Baffle Agitator Baffle Determine that the Drain Valve Handle is securely attached to the drain valve and t...

Страница 23: ...replaced 2 Check the following components and replace if found to be defective Transformer Gas Control Valve Hi Limit Switch 1 Blower may have over heated and shut off on thermal overload If this sit...

Страница 24: ...24 30A215 Mar2008 CLEANING PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 25: ...oths cleaners powders metal knife spatula or any other metal object to scrape stainless steel Scratches on stainless steel are almost impossible to remove b Filter shortening in each fryer once a day...

Страница 26: ...26 30A215 Mar2008 FRYER OPERATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 27: ...r the 3 RED Heating Indicator The following controls are located behind the 4 Service Access Door 7 Drain Valve with 8 Handle 9 Drain Valve Extension 6 Combination Gas Valve 11 Manual Shutoff Valve an...

Страница 28: ...e programming mode b In programming mode allows access to the operating mode 3 HEAT DEMAND LEDs When lit bright indicate the computer is calling for heat 4 TEMPERATURE KEY a When pressed one time disp...

Страница 29: ...tion ie 10 00 Time remaining in the BOIL mode ie 20 00 Prompt to cycle power OFF at the end of the BOIL FILTER etc functions Indicate the specific Product Key number for which the computer is displayi...

Страница 30: ...is more than 20 F 11 C below the READY SET POINT temper ature B The HEAT DEMAND lamp on the computer and the RED Heating Indicator lamp on the fryer will cycle ON and OFF until the Set Point Tempera t...

Страница 31: ...TIONS MANAGER SUPERVISOR OR A SERVICE AGENT APPROVED BY ULTRAFRYER SYSTEMS CUSTOMER SERVICE DEPARTMENT 1 RECIPE PROGRAM DISPLAYS NOTE A programming timeout will occur if no key is pressed for TWO 2 mi...

Страница 32: ...IT Key for this temperature to be accepted i e STEP 1 360 F 204 C NOTE If 00 00 is entered programing for this PRODUCT KEY is ended D Repeat Steps 6A 6B and 6C to program the START TIME TIMING MODE an...

Страница 33: ...cating the burner is periodically being turned ON and OFF to heat the shortening gradually 2 When the heat exchanger tubes are COMPLETELY covered with LIQUID shortening and the shortening is ABOVE the...

Страница 34: ...le obtaining maximum usage of the shortening I DO USE A HIGH QUALITY SHORTENING TO ACHIEVE A CONSISTENT QUALITY PRODUCT AND LONG TERM SAVINGS II DO NOT SALT PRODUCTS OVER THE FRYER AS SALT QUICKLY DET...

Страница 35: ...35 30A215 Mar2008 TECHNICAL ASSISTANCE ORDERING INFORMATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 36: ...prior to departure of the delivering carrier Any damage must be noted on the receiving document to facilitate filing of freight claims Carriers must be notified immediately and freight inspections mus...

Страница 37: ...37 30A215 Mar2008 RECOMMENDED SPARE PARTS PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 38: ...e local area GAS FRYER RECOMMENDED SPARE PARTS LISTING Description PN Ignitor Spark Module 18179 24 Volt Stepdown Transformer 18180 24 Volt Combination Gas Control Valve 18227 Air Pressure Switch 18A2...

Страница 39: ...39 30A215 Mar2008 PARTS IDENTIFICATION PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 40: ...andles 19B160 9 Door Magnetic Catch 22407 10 P3 Venturi Short Side Burner 22A341 11 1 2 13mm Manual Gas Valve w RED Handle 24326 12 NATURAL GAS 105k Orifice Plug w 10 Drill Hole Uses Orifice Holder PN...

Страница 41: ...18A072 5 120 to 24 Volt Computer Transformer 18A047 6 Chrome Door Pull 22005 7 Right Hand Door Lift Off Hinge 22640 8 120 Volt 1 3 Watt Snaplight w RED lens 23043 9 24 Volt DC Control Relay 23A023 NO...

Страница 42: ...ouble Blower 19B115 6 Exhaust Blower Motor Kit Order PN 19A545 F Blower Gasket 19B944 7 3 16 5mm ID rated at 500 F 260 C Air Pressure Tube 24A068 8 Medium Duty 3 76mm Caster w out Brake 28A011 9 Type...

Страница 43: ...t the fryer s electrical plug to a receptacle The Fryer will turn ON 7 Adjust the plate over the flue outlet until the pressure meter reads 1 3 PSI 8 Adjust the set screw on the AIR SWITCH so the Volt...

Страница 44: ...44 30A215 Mar2008 WIRING DIAGRAM PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 45: ...may occur in the future use the diagram posted to the fryer for circuit trac ing and or trouble shooting a fryer 14 356 mm PD GAS FRYER W COMPUTER WIRING DIAGRAM PDF compression OCR web optimization u...

Страница 46: ...46 30A215 Mar2008 THIS PAGE INTENTIONALLY BLANK PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Отзывы: