INSTRUCTION MANUAL 

 

 

1000 KW RESISTIVE LOAD BANK 

 

 

MODEL NO. TLB-R1000-480-OS 

 
 

Published by: 

 Universal Load Banks, LLC. 

28200 Lakeview Drive 

Wixom, MI  48393

 

 

Customer Service: 

E-mail:  

[email protected]

 

Website: 

www.universalloadbanks.com 

Phone:  248-571-4125 

 

 

 
 
 
 
 
 

 
 
 
 
Date of Original:

  2016 October  

 
 

Содержание TLB-R1000-480-OS

Страница 1: ...ession use copying or disclosure by anyone without express written permission of ULB is not authorized and may result in criminal and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO AL...

Страница 2: ...sclosure by anyone without express written permission of ULB is not authorized and may result in criminal and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_R...

Страница 3: ...Page 3 of 35 ABBREVIATIONS AND ACRONYMS The following is a list of abbreviations and acronyms used throughout this manual A Amperes Amps AC Alternating current AI Analog Input AO Analog Output CMM Com...

Страница 4: ...AY FROM LIVE CIRCUITS 5 SHOCK HAZARD 5 DO NOT SERVICE OR ADJUST ALONE 5 SAFETY EARTH GROUND 5 CHEMICAL HAZARD 5 EMERGENCY AID 5 POTENTIALLY HAZARDOUS OPERATOR CONDITIONS 5 EMERGENCY SHUT DOWN 6 SAFETY...

Страница 5: ...Do not replace components or make adjustments to equipment with power turned on To avoid casualties always remove power to the entire system Turn off and disconnect the main power source under test D...

Страница 6: ...ime after operation as these surfaces become hot and may result in a serious burn injury Never bypass any blown fuse Replace any indicator lamps on the operator control panel as required Each indicato...

Страница 7: ...he following safety warnings appear in the text where there is danger to operating personnel They are noted and repeated here for emphasis WARNING Disconnect unit from all power sources before any dis...

Страница 8: ...should occur after receiving the unit Periodic preventative maintenance and inspections should be performed to ensure system reliability Upon receipt of your Load Bank be sure to carefully unpack the...

Страница 9: ...be used without the Fan Blower Motor operating Inadequate cooling airflow will result in resistor load elements overheating fire hazard and danger to personnel Operating Instructions General All insta...

Страница 10: ...e NEC National Electric Code or any local codes Correctly sized copper compression lugs are recommended The Load Bank has three main input load bus bars marked L1 L2 and L3 Load cable connections are...

Страница 11: ...L TLB R1000_480_MANUAL_Rev03 docx Page 11 of 35 Use HMI display touch screen to set require KW Minimum KW resolution that can be selected is 25KW Set desired time duration in Hours HR and Minutes MIN...

Страница 12: ...ocx Page 12 of 35 Safeties Any alarm condition existing in the load bank is indicated by LOAD BANK SAFETY NOT OK indication on the top right corner of the main screen on HMI To investigate safety NOT...

Страница 13: ...wer E stop Loss of control power or E stop is operated Table 1 All load steps are disabled and load cannot be applied unless all above parameters in OK status Green Color Note Ensure and check for pro...

Страница 14: ...riminal and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 14 of 35 Power data 1 Power data display Click POWER DATA button on main screen and...

Страница 15: ...inal and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 15 of 35 WARNING While Load bank is running with load applied condition setting Load D...

Страница 16: ...l liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 16 of 35 Load Profile Using this feature load bank can be configured to operate at various load condit...

Страница 17: ...Fig 5 Load Profile 3 Enter require Hr Min and KW values for each step and click ACTIVATE button a Now Load bank will start operating with Hr Min and KW values selected for step 1 This will be indicate...

Страница 18: ...hnical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 18 of 35 e Load bank will continue to operate at KW values Hr and Min selected for step 1 then after step 2 will be activated...

Страница 19: ...al and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 19 of 35 Operating Multiple Load banks Multiple load banks Max 5 can be operated in Mast...

Страница 20: ...screen shown below Refer maintenance section below to know how to access this screen on the display 1 Each Load bank should have unique ID anywhere from 1 16 assigned 2 The First load bank in the net...

Страница 21: ...bank should have following settings in above screen THIS LOAD BANK TO OPERATE AS SLAVE THIS LOAD BANK ID 4 Tip Next higher number from Slave 2 Load bank ID ID OF SLAVE 1 LOAD BANK Not applicable Slav...

Страница 22: ...03 docx Page 22 of 35 Powering up Master Slave Load banks Note For master to identify all salves load banks master load bank should be powered up last i e power up all slave load banks first or all lo...

Страница 23: ...permission Possession use copying or disclosure by anyone without express written permission of ULB is not authorized and may result in criminal and or civil liability U ILB 5_Technical Manual TLB R10...

Страница 24: ...l TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 24 of 35 WARNING Load bank should never be operated in Master Slave mode if any of the COMM Communication status indicator on above scree...

Страница 25: ...Page 25 of 35 Data Logging 1 Insert USB stick in USB port on the back of HMI display 2 Click DATA LOGGING button will show following screen See Fig 11 Fig 11 Data Logging 1 Click START LOGGING will s...

Страница 26: ...closure by anyone without express written permission of ULB is not authorized and may result in criminal and or civil liability U ILB 5_Technical Manual TLB R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Re...

Страница 27: ...circuits WARNING DO NOT touch the exhaust louver during operation Hot Air exhaust will cause serious burns DO NOT allow objects to enter or block air intake or exhaust louvers DO NOT operate the Load...

Страница 28: ...his load bank WARNING Stop Load Test before entering in to this set up screen Setting should be changed by only qualified person who clearly understands implication of changing each setting A pop up w...

Страница 29: ...injury from electrical shock or from moving fan blades could result unless all sources of power are completely disconnected before servicing Maintenance must always be done by qualified technician Ma...

Страница 30: ...ened and elements are clear and free of debris 6 Inspect all resistors for mechanical and structural integrity and location Replace any excessive sagging resistor elements ceramics and support rods Re...

Страница 31: ...jumper are tightened to 15 in lb and ceramic tubes spring bushings are tightened to 9 in lb Inspect all ceramic bushings and insulators for cracks Replace all broken or cracked ceramic insulators Ensu...

Страница 32: ...ng coil or on operator control unit main power blower start stop pushbuttons Blower Motor fuse is blown check and replace as required Motor Over Load relay is tripped Motor starting relay failed Fan b...

Страница 33: ...nnot be energized Blower Failure Air failure Over Temp Wrong Voltage Motor Overload Load Dump see item 2 thru 8 above Load Dump switch is operated One or more of the branch circuit load step fuses for...

Страница 34: ...f time indoors cover the unit to prevent any accumulation or buildup of dust or dirt If stored outdoors do not cover with plastic that may create condensation and enclosure corrosion or staining keep...

Страница 35: ...R1000 480 OS_NO ALL TLB R1000_480_MANUAL_Rev03 docx Page 35 of 35 Customer Service Any maintenance or service procedure beyond scope of those provided in this manual should be referred to a factory en...