Parameter
Default
Value
Description
SOUNDING_MODE
SOUNDING
Possible values are:
• SOUNDING: Normal operation
mode
• CALIBRATION: Sine wave with
frequency 20 MHz
• TEST: Sine wave with constant
period for any settings
SAMPLE_COUNT
256
Sample count per trace:
128, 256, 512, 1024
TELEMETRY_PERIOD_MS
2000
Telemetry data refresh rate, ms
TIME_RANGE_NS_1
300
Trace time range for the first channel,
ns:
50, 100, 200, 300, 500, 800, 1200,
2000.
This parameter is also applicable in
single-channel mode and with the
Aero
version.
Trace time range for the
Aero
version,
ns:
50, 100, 200, 300, 500.
TIME_RANGE_NS_2
300
Trace time range for the second
channel, ns.
See
TIME_RANGE_1
values.
Note: When using the
Aero
version of RadSys Zond radar, all fields are ignored apart
PULSE_DELAY_1
and
TIME_RANGE_NS_1
.
GPR Configuration
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
110
Revision 5 • November 2021