3. Set the trace time range, sample count, pulse delay, and filter in the corresponding
fields in the
[RADSYS_ZOND]
section:
[RADSYS_ZOND]
FILTER_1=OFF
FILTER_2=OFF
MODE=TWO_CHANNELS
PULSE_DELAY_1=297
PULSE_DELAY_2=301
SAMPLE_COUNT=256
TIME_RANGE_NS_1=300
TIME_RANGE_NS_2=300
Note: When using the
Aero
version of RadSys Zond radar, all fields are ignored apart
PULSE_DELAY_1
and
TIME_RANGE_NS_1
.
4. While using dual-channel mode one may setup the antenna offsets in the
corresponding fields:
[RADSYS_ZOND]
OFFSET_FORWARD_M_1=0.1 ; 10 cm alongside the heading line
OFFSET_FORWARD_M_2=0.1
OFFSET_RIGHT_M_1=0.25 ; 25 cm alongside the traverse line
OFFSET_RIGHT_M_2=-0.25 ; -25 cm alongside the traverse line (left offset)
See
High Frequency GPR Configuration
to find all available settings with default values and
descriptions.
Ground-Penetrating Radar Setup
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
65
Revision 5 • November 2021