Parameter
Default
Value
Description
BAUD_RATE
115200
UART baud rate, bps
DEADZONE_HIGH_MM
500
Near field zone where detection is
ignored for high acoustic frequency,
mm
DEADZONE_LOW_MM
1000
Near field zone where detection is
ignored for low acoustic frequency,
mm. To support D032 model
recommend changing the value to 1500
mm.
FREQUENCY_HIGH_HZ
200000
High acoustic frequency, Hz
FREQUENCY_HZ
10
Measuring frequency, Hz
FREQUENCY_LOW_HZ
50000
Low acoustic frequency, Hz. To support
D032 model change the value to 30000
Hz.
GAIN_HIGH_DB
0
Amplifying gain for high acoustic
frequency, dB
GAIN_LOW_DB
0
Amplifying gain for low acoustic
frequency, dB
MAX_SENSOR_ANGLE_DEG
10
Data filtering by tilt. The data are not
recorded if the sensor tilt value is
greater than the specified value, degree.
MIN_SENSOR_DEPTH_M
0.1
Data filtering by sensor dept in the
water.
Sensor depth is calculated as a
difference between the length of the
cable (set by CABLE_LENGTH_M
parameter in the ECHOSOUNDER
section) and current altitude.
The data are not recorded if the sensor
depth is lower than specified value, m.
MODE
NMEA
• NMEA: Ouptut data in NMEA
format only
• ECHOSOUNDER: Output data in
NMEA and SEG-Y formats
Echosounder Configuration
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
113