Remote Water Sampling Setup
1. Set
DROP_MESSENGER
item to
true
in
[PAYLOADS]
section:
[PAYLOADS]
DROP_MESSENGER=true
2.
DROP_MESSENGER
plugin has only one purpose is to drop messenger to close Ruttner
water sampler. UgCS SkyHub drops the messenger using servo controlled through
PWM. By default, it’s used the following PWM settings:
[DROP_MESSENGER]
SERVO_LOCK_PULSE_MS=1.5
SERVO_PERIOD_MS=10
SERVO_UNLOCK_PULSE_MS=0.5
See
to find details and descriptions.
Anemometer Setup
There are common anemometer settings in the
[ANEMOMETER]
section. Check whether
minimum and maximum values correspond to your needs:
[ANEMOMETER]
MIN_WIND_SPEED_MPS=0
MAX_WIND_SPEED_MPS=10
These values are used to bound valid wind speed values. When the wind speed is out of the
limits, the operator will be notified.
FT Technologies FT742-SM Setup
1. Set
FTTECHNOLOGIES_FT742_SM
item to
true
in
[PAYLOADS]
section:
[PAYLOADS]
FTTECHNOLOGIES_FT742_SM=true
See
FT Technologies FT742-SM Configuration
to find all available settings with default values
and descriptions.