Version 1
7
Basic Components
Plug-in modules scanning module
This module is utilized to receive air-borne ultrasound such as the ultrasounds emitted by
pressure/vacuum leaks and electrical discharges. There one male plug at the rear of the module.
For placement, align the plug with the corresponding receptacle in the front end of the pistol
housing and plug in. The Scanning Module has a piezoelectric transducer to pick up the airborne
ultrasound.
Stethoscope (contact) module
This is the module with the metal rod. This rod is utilized as a “waveguide” in that it is sensitive to
ultrasound that is generated internally such as within a pipe, bearing housing or steam trap. Once
stimulated by ultrasound, it transfers the signal to a piezoelectric transducer located in the module
housing directly behind the “wave guide”. For placement align the plug with the corresponding
receptacle in the front end of the pistol housing and plug in.
Pistol-grip housing display panel
In the Operation Mode the Display Panel will show intensity levels (as dB and as a bar graph),
Sensitivity Level, Storage location number, and Battery Level,. Intensity levels are shown
simultaneously as a numeric dB value and on
sixteen-segmented bar graph (with each segment
representing 3 dB). This Ultraprobe receives ultrasound centered around 40 kHz and is non-
adjustable.
1
3
2
1
Display Panel
2
Headphone Jack
3
Sensitivity Control/ Storage Entry Dial