LISA-U1 series - System Integration Manual
3G.G2-HW-10002-3
Preliminary
Design-In
Page 109 of 125
Category
Application
Immunity Level
Contact Discharge to coupling planes (indirect contact discharge)
Enclosure
+2 kV / -2 kV
+4 kV / -4 kV
Contact Discharges to conducted surfaces (direct contact discharge)
Enclosure port
Not Applicable
6
Contact Discharges to conducted surfaces (direct contact discharge)
Antenna port
(only antenna with completely
insulating surface can be used)
Not Applicable
7
Air Discharge at insulating surfaces
Enclosure port
Not Applicable
8
Air Discharge at insulating surfaces
Antenna port
(only antenna with completely
insulating surface can be used)
+2 kV / -2 kV
+4 kV / -4 kV
+8 kV / -8 kV
Table 39: Enclosure ESD immunity level result, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” for LISA
application reference design.
2.5.1
General precautions
The following module interfaces can have a critical influence in ESD immunity testing, depending on the
application board handling. The following precautions are suggested:
RESET_N pin
Sensitive interface is the reset line (
RESET_N
pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination
connected to the
RESET_N
pin to avoid a module reset caused by an electrostatic discharge applied to the
application board enclosure
A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the
RESET_N
pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure
It is recommended to keep the connection line to
RESET_N
as short as possible
6
LISA mounted on application design:
Not Applicability -> EUT with insulating enclosure surface, EUT without enclosure surface
Applicability -> EUT with conductive enclosure surface
7
LISA mounted on application design:
Not Applicability -> Antenna with insulating surface
Applicability -> Antenna with conductive surface
8
LISA mounted on application design:
Applicability -> EUT with insulating enclosure surface
Not Applicability -> EUT with conductive enclosure surface, EUT without enclosure surface