LISA-U1 series - System Integration Manual
3G.G2-HW-10002-3
Preliminary
Design-In
Page 107 of 125
Reported values close to the used diagnostic resistor nominal value (i.e. values from 13 k
Ω
to 17 k
Ω
if a
15 k
Ω
diagnostic resistor is used) indicate that the antenna is properly connected
Values close to the measurement range maximum limit (approximately 50 k
Ω
) or an open-circuit
“over range” report (see
u-blox AT Commands Manual
[2]) means that that the antenna is not connected or
the RF cable is broken
Reported values below the measurement range minimum limit (1 k
Ω
) will highlight a short to GND at
antenna or along the RF cable
Measurement inside the valid measurement range and outside the expected range may indicate an improper
connection, damaged antenna or wrong value of antenna load resistor for diagnostic
Reported value could differ from the real resistance value of the diagnostic resistor mounted inside the
antenna assembly due to antenna cable length, antenna cable capacity and the used measurement method