Doc No. FM0713 Issue C Page 6
10 Pair Distribution Bus
10 Pair Digital Door Panel Bus
Main Entrance
Digital Door Panel
Floor Level 1
Floor Level 2
Floor Level 1
Functional Door Panel
Door
Lock
Exit
Button
Door
Contacts
Floor Level 2
Functional Door Panel
Max 255
Distribution Nodes
Max 8 or 16
Ground Floor
Flats per
System Node
Lock
PSU
240V AC
Door
Lock
Exit
Button
Door
Contacts
Lock
PSU
240V AC
Exit
Button
Door
Contacts
Door
Lock
240V AC
To next
Floor
Telephones
connected
to both
Distribution
Nodes
Telephones
connected
to both
Distribution
Nodes
Ground Floor
3. MULTIPLE SPEECH PATHS - OPTION 2 DECK ACCESS
To help speed the passage of visitors through large deck access systems the floor level functional panels can be
connected to additional distribution nodes to provide an additional speech path per floor. The example below
would allow all floor level functional panels and the main entrance door panel to be used at the same time to
call different flats.
Note: Trade and power connections must be linked between the distribution nodes on each floor level.
Additional lock power supplies are recommended for each door panel or a boxed PAC Easikey 250 could be used
for every 2 floors.
4 Pair to each Flat
10 Pair
10 Pair
4 Pair to
each Flat
4 Pair to
each Flat