Doc No. FM0713 Issue C Page 5
2 x 10 Pair
Distribution
Bus
2 x 10 Pair Door Panel Bus
Main Entrance
Digital Door Panel
Floor Level 1
Floor Level 2
Max 255
Distribution Nodes
16 Port
System
Node
Telephones
connected
to both
Distribution
Nodes
Exit
Button
Door
Contacts
Door
Lock
240V AC
To next
Floor
Rear Entrance
Digital Door Panel
Exit
Button
Door
Contacts
Door
Lock
Ground Floor
Telephones
connected
to both
Distribution
Nodes
Telephones
connected
to both
Distribution
Nodes
2. MULTIPLE SPEECH PATHS - OPTION 1 DIGITAL
On multi-entrance systems multiple speech paths can be achieved by fitting extra distribution nodes and
wiring the telephones/video phones to multiple nodes. The example below shows a 2 entrance digital system
with 2 speech paths, i.e. both door panels can be used at the same time to call different flats.
Note: for 3 door panels with 3 speech paths telephones would need to be connected to 3 distribution nodes.
4 Pair to
each Flat
4 Pair to
each Flat
4 Pair to
each Flat