13
4.2
Keyboard
The
keyboard
is
mounted
to
and
directly
connected
to
the DIG-T2
board and functions as an MMI (Man-Machine Interface). The keypad
serves as a control panel containing the command and programming
keys. It also includes an LCD display with two rows of 16 characters
for cycle progress updates and error messages. In addition it contains
the following light indicators:
— START
(autoclave in process),
— FAIL
(the process failed),
— WATER
(no water in the reservoir),
— DOOR
(blinks with buzzer sound when START is
pressed and the door is not closed).
For more detail on the control keys and error messages please see the
EHS Operators Manual
4.3
Digital Board DIG - T2
The digital board contains the microprocessor that runs the system
software program and controls all the functions of the EHS autoclave.
It is connected to the Keypad and digital display for interactive
communication with the operator. It is also connected to the ANL-T2
analog board for communication with the rest of the EHS autoclave. In
addition the DIG-T2 board has PC and printer communication abilities.
— The digital board is connected to the keypad and the ANL-T2
analog board via ribbon cables.
The DIG-T2 board receives human commands through the Keypad
and transmits visual information back, through the Keypad display
The DIG-T2 board receives sensory information, from system
sensors, in the form of digital signals through the ANL-T2 board. It
also transmits operational commands, in the form of digital signals,
to the various system components through the ANL-T2 board.
Power for the DIG-T2 is provided by the ribbon cable connected to
the ANL-T2
— The digital board also contains a parallel printer port for connection
to a proprietary printer. The printer is connected directly to this
board through connector DS1 via a ribbon cable. The printer
receives data and operating voltage directly from this connector.
— The PC interface establishes two-way communication between the
DIG-T2 board and a stand-alone personal computer, utilizing
proprietary software. This communication is via a connector
located on the ANL-T2 board and ribbon cable leading to an
external connector on the front panel.
— On the board, are three types of memories:
1) EPROM memory (U15) for storing the program codes.
2) RAM memory (U9) with a capacity of 64KB for the storage of
temporary
data
during
the
running
of
the
program
that
is
located on the opposite side. This information is only for
general knowledge.
Содержание 2540 EHS
Страница 10: ...9 REAR VIEW...
Страница 17: ...16 Layout diagram of the ANL T2 is provided below ANL T2 BOARD Top View Bottom View...
Страница 19: ...18 AC T1 BOARD Top View Bottom View...
Страница 30: ...29 6 4 Input Output Graph...
Страница 31: ...30...
Страница 32: ...31...
Страница 33: ...32...
Страница 34: ...33...
Страница 35: ...34...
Страница 66: ...65...
Страница 68: ...67...
Страница 120: ...119 VESSEL ASSEMBLY Model 2540 EHS Model 3870 EHS...
Страница 121: ...120 OUTER CABINET ASSEMBLY Model 2540 EHS Model 3870 EHS...
Страница 122: ...121 TRAY HOLDER For model 2540 TRH254 0009 For model 3870 TRH387 0001...
Страница 123: ...122 TRAY TRAY HANDLE CMT240 0001 MODEL SIZE CAT No 2540 TRY240 0001 Big TRY387 0001 3870 Small TRY387 0003...
Страница 126: ...125 PIPING DRAWING FOR 2540 EHS...
Страница 127: ...126 PIPING DRAWING FOR 3870 EHS...
Страница 128: ...127 ELECTRICAL DRAWING FOR 2540 EHS...
Страница 129: ...128 ELECTRICAL DRAWING FOR 3870 EHS TILL S N 2307039...
Страница 130: ...129 ELECTRICAL DRAWING FOR 3870 EHS AFTER S N 2307040...