Start-up and operation
66
5816,0013US / Version 02
10.5 Putting the barrier temporarily out of operation
High wind speeds
WARNING
Risk of injury from barrier arm in case of high
wind speeds!
The barrier arm is no longer securely locked with
the mains voltage off. At high wind speeds, the
barrier arm can be pressed from its end position.
The moving barrier arm can severely injure a
person.
– Keep supplying the barrier with mains voltage.
– Remove the barrier arm if necessary.
NOTICE
Possible damage to the equipment by
condensed water when mains voltage is
switched off!
– Keep supplying the barrier with mains voltage.
If the barrier is put out of operation for a longer period, proceed as
follows:
1.
Switch off barrier.
See page 64, chapter 10.3.
2.
Remove the barrier arm if necessary.
chapter 13.2.
3.
Protect the barrier from corrosion and contamination.
4.
Switch on barrier.
See page 64, chapter 10.3.
Traffic H1 Swing Gate Horizontal Barrier