Malfunctions
80
5816,0013US / Version 02
12.3.3
Event, warning and error messages – Detector
The warning messages "FF4B" and "FF4C" are also reported
through the output function "Error".
Number
Description
Possible cause
Corrective action
FF4A
ERROR
Hardware error
Internal HW function test failed
Perform reset.
See
page 81, chapter 12.4.
Contact service if required.
FF4B
WARNING
Loop error A or C
Short circuit or idle loop A or C
Remove loop error and
perform adjustment.
If no loop is connected,
select the option "Inactive"
in the menu "Detector".
FF4C
WARNING
Loop error B or D
Short circuit or idle loop B or D
Remove loop error and
perform adjustment.
If no loop is connected,
select the option "Inactive"
in the menu "Detector".
Table 13: Event, warning and error messages – Detector
12.3.4
Event, warning and error messages – All modules
Number
Description
Possible cause
Corrective action
6010
WARNING
Watchdog reset
SW error
Contact service if required.
8110
WARNING
Bus fault
Warning
Contact service if required.
8120
WARNING
Bus HW fault
Warning
Check DIP switch next to
service interface (position
ON)
Remove devices at service
interface if required.
Table 14: Event, warning and error messages – All modules