Assembly and installation
5816,0013US / Version 02
39
Laying the foundation,
Installing empty conduits
A
A
1
2
3
4
5
Mag00155
6
7
(135)
5.31
(135)
5.31
(160)
6.30
7.09
6.30
(160)
23.6
(600)
17.7
(450)
19.7
(500)
(180)
(180)
7.09
min.
31.5
(800)
Fig. 9: Foundation plan
Dimensions in inch or feet are without parenthesis. Dimensions in
mm are in parenthesis.
1
Foundation anchor (4 pcs.)
2
Optional when using loop connection;
empty conduit for loop connection, diameter: 1.14 in (29 mm)
3
Empty conduit for induction loop, diameter: 1.14 in (29 mm)
4
Empty conduit for control lines, diameter: 1.14 (29 mm)
5
Concrete foundations (C35/45 XD3 XF2)
6 Roadway
7
Foundation depth: at least 31.5 in (800 mm), frost-protected
foundation depth to be adjusted to the local situation.
1.
Dig foundation hole pursuant to Fig. 8 and Fig. 9.
Mag00156a
4 x
0.31
Æ
12.6 x 26.4
6 x
13.4 x 15.4
Æ
0.31
4 x
14.6 x 27.2
Æ
0.31
(4 x
Æ
8 320 x 670)
(6 x
8 340 x 390)
Æ
(4 x
8 370 x 690)
Æ
Fig. 10: Reinforcement grid
Dimensions in inch or feet are without parenthesis.
Dimensions in mm are in parenthesis.
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099
Содержание Traffic H1
Страница 89: ...Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...
Страница 94: ......
Страница 96: ......
Страница 98: ......