Setting
Setting by manual bridging (shorting)
36
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Window function – setting the switching range
Window function
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 8 s
13 s
LED YE 2 × 1 Hz
Measure and save
SP1
Fail
LED GN/YE
1.5 s × 5 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 2 Hz
Measure and save
SP2
OK
LED GN
1.5 s × 5 Hz
Normal
operation
U
B
/T2 > 2 s
LED YE
1 × 8 Hz
Cancel
Fig. 31: Window function – setting the switching range
Position the object for switching point 1.
Store switching point 1: Bridge pin 3 (BU) with pin 5 (GY) for 8…13 s.
Position the object for switching point 2.
Store switching point 2: Bridge pin 3 (BU) with pin 5 (GY) for 2…7 s.
a
The switching points have been successfully taught in if the green LED flashes for 1.5 s at
a frequency of 5 Hz.