Connection diagram of the master sensor in synchronization mode
Pin
Pin assignment
Pin 1
+24 VDC
4 BK
1 BN
3 BU
2 WH
5 GY
Pin 2
Output 2 (analog output or switching output)
Pin 3
GND
Pin 4
Synchronization output, connected to pin 5 of the
slaves
Pin 5
Not connected (n. c.)
Connection diagram of the slaves in synchronization mode
Pin
Pin assignment
Pin 1
+24 VDC
4 BK
1 BN
3 BU
2 WH
5 GY
Pin 2
Output 2 (analog output or switching output)
Pin 3
GND
Pin 4
Output 1 (switching output)
Pin 5
Synchronization input, connected to pin 4 of the
master sensor
6.4
Connection – release mode
Connection diagram of the sensors in release mode
Pin
Pin assignment
Pin 1
+24 VDC
4 BK
1 BN
3 BU
2 WH
5 GY
Pin 2
Output 2 (analog output or switching output)
Pin 3
GND
Pin 4
Output 1 (switching output)
Pin 5
Release input
Enable: +24 VDC
Disable: GND or open
6.5
Connection – throughbeam mode
Pin assignment of the emitters in throughbeam mode
Pin
Pin assignment
Pin 1
+24 VDC
4 BK
1 BN
3 BU
2 WH
5 GY
Pin 2
No function
Pin 3
GND
Pin 4
Trigger output, connected to pin 5 of the receiver
Pin 5
Not connected (n. c.)