V2.0 | 2021/06
47
Inverting the output function (NO/NC)
Invert logic
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
GND/T1 > 14 s
LED YE 3 × 1 Hz
Invert
NC
LED YE
1.5 s × 5 Hz
NO
LED GN
1.5 s × 5 Hz
Normal
operation
Fig. 42: Inverting the output function (NO/NC)
Select the switching output.
Press and hold down pushbutton 1 for 14…19 s.
a
The output function has been successfully inverted as an NO contact if the green LED
flashes for 1.5 s at a frequency of 5 Hz.
a
The output function has been successfully inverted as an NC contact if the yellow LED
flashes for 1.5 s at a frequency of 5 Hz.