Setting
Setting via IO-Link
52
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Setting output 2 as a switching output
Out2: set
Current output
Voltage output
Switch only:
inverted Out1
U
B
/T2 > 2 s
7 s
LED YE 1 × 1 Hz
U
B
/T2 >
8 s
16 s
LED YE 2 × 1 Hz
U
B
/T2 >
14 s
19 s
LED YE 3 × 1 Hz
OK
LED GN
1.5 s × 5 Hz
Normal
operation
Fig. 47: Setting output 2
Press and hold down pushbutton 2 for 14…19 s.
a
Output 2 is set successfully as a switching output if the green LED flashes for 1.5 s at a
frequency of 5 Hz.
9.4
Setting via IO-Link
The following components are required for setting the device via IO-Link:
Hardware
Software
Documentation
n
USB IO-Link adapter
USB-2-IOL-0002
n
PACTware parameter
software
n
DTM IODD Interpreter
n
IODD configuration file for
RU Series ultrasonic sensors
n
IO-Link Devices
Commissioning (D900633)
n
IO-Link parameters manual
Further information on operating modes and parameters in IO-Link mode is provided in the
IO-Link Parameters manual.