Attention
Possible device damage with BL20!
The power supply of the read/write heads must not be connected via the BL20 base modules,
since the current via the RFID I/O modules is not sufficient. Whilst the wiring of the data
cables is routed via the base modules, the power supply must be fed directly via the supply
lines of the cables .../S2500, .../S2501 and .../S2503!
Overview of the TURCK BL ident® UHF system
D101925 0412 -
BLident®
UHF
2-12
2.6.2
LED functions of the read/write heads
Refer to the enclosed instruction leaflets of the devices for the LED function of the read/write heads.
Note
The functions of the LEDs can be assigned as required and differently to the standard
configurations described in the enclosed instruction leaflets. For this use the RDemo and
WebConfig software tools in conjunction with the STW-RS485-USB interface converter
(Ident no. 7030354).