Start-up
D101925 0412 -
BLident®
UHF
3-12
With the
BL ident®
system, TURCK offers different PIB variants to suit the read and write requirements of
different data volumes:
PIB_001KB
PIB_016KB
PIB_032KB
3.2.3
Start-up with the PIB and Siemens PLCs
The following gateways and compact stations are only suitable for start-up with the PIB using the
Siemens S7-300 and S7-400 controllers:
With the
BL ident®
system, TURCK offers different PIB variants to suit the read and write requirements of
different data volumes:
PIB_001KB
PIB_016KB
PIB_032KB
3.2.4
The PIB_001KB function block
In the CoDeSys software, the program block PLC_PRG represents the highest program level to be
processed cyclically by the CPU.
To view this level choose the Blocks tab and open the display of the function block by double-clicking
PLC_PRG(PRG) (see
Figure 6: “PIB function block” page 3-13
).
The first channel of a BLxx-2RFID-A module can be commissioned in this example project.
The suffix CH_0 here stands for the first channel.
Note
Refer to the manual D101639 - Start-up with CoDeSys for programmable gateways for a
detailed description.
Table 17:
Gateways for
PROFIBUS-DP
and PROFINET IO
Fieldbus system
BL20 type
designation
BL67 type
designation
BLcompact type
designation
PROFINET IO
On request
BL67-GW-EN-PN
On request
PROFIBUS-DP
BL20-GW-DPV1
BL20-E-GW-DPV1
BL67-GW-DPV1
BLCDP-2M12MT-
2RFID-A
Note
Refer to the manual D101579 - Start-up with PROFIBUS DP and D10648 - Start-up with
PROFINET for a detailed description.