5-10
SECTION 5
TEST RESULTS
MAINT TEST ALARM
Test Alarm Maintenance Message
—
This
message is displayed when the TEST ALM CR or
TEST ALM RC message is detected in the main-
tenance field. It indicates an error has been
detected in the maintenance test and the test
should be aborted.
DATALINK SYNC LOSS
Datalink Synchronization Loss
—
This mes-
sage is displayed when SLC datalink synchroni-
zation has been lost. If a category other than
SUMMARY is selected when the datalink syn-
chronization is lost, the display alternates be-
tween the selected test result and DATALINK
SYNC LOSS message until datalink synchroni-
zation returns.
NO DATALINK SYNC
No Datalink Synchronization
—
This mes-
sage is displayed when the T-BERD 107A has
failed to obtain SLC datalink synchronization.
The following SUMMARY category PRM test
results are received from the ESF datalink. The
Enhanced ESF Option is required for these test
results. If a “~” (tilde symbol) precedes a far end test
result, it indicates the results are an approximate
value due to lost PRMs.
FAR FRM ES
Far-End Frame Error Seconds
— A count of
the seconds in which one or more frame errors
occurred in the received signal at the far end.
This result reports on the PRM
Frame-Synchronization-Bit Error Event Bit
(FE = 1) status.