5-9
SECTION 5
TEST RESULTS
SHELF x ON PROT
Shelf x on Protection Line
—
This message is
displayed when the indicated shelf (x = A, B, C,
or D) has been switched to the protection shelf.
Three consecutive datalink frames must indi-
cate that a shelf has been switched to the protec-
tion shelf before this alarm message is displayed.
MINOR ALARM
Minor Alarm
—
This message is displayed
when a minor alarm condition exists.
PWR/MISC ALARM
Power/Miscellaneous Alarm
—
This message
is displayed when a power/miscellaneous alarm
condition exists on a specific shelf.
MAINT HOOK/SEIZE
On-Hook/Seize Maintenance Message
—
This
message is displayed when the ON-HOOK or
SEIZE RC message is detected in the mainte-
nance field. It indicates that either the line is
being released at the end of the test or seized at
the beginning of the test.
MAINT PROCEED
Proceed Maintenance Message
—
This
message is displayed when the PROCEED CR
or PROCEED RC message is detected in the
maintenance field. It indicates that the system
is ready to proceed with the test.