SECTION 4
4-11
AUXILIARY
FUNCTIONS
transmitted from left to right as displayed. The pro-
grammed loop-up code is transmitted when the
LOOP
CODES
switch is set to PROG and the
LOOP UP
switch is pressed.
When the T1, T1 D4, T1 D1D, or T1 SLC mode
is selected, the loop code is transmitted as an in-band
loop code. When the T1 ESF mode is selected, the
loop code can be transmitted in-band or out-of-band
depending on the AUX CSU LOOP function setting.
Use the following procedure to program the
loop code.
1.
AUX and PATTERN switch
Press the
AUX
switch to activate the auxiliary
functions. Press the
PATTERN
switch to
select the AUX PGM LPUP function.
2.
CATEGORY switch
Press the up or down arrow to move the
cursor (blinking bit) to the bit to be toggled.
The up arrow moves the cursor forward
(FWD) from left to right. The down arrow
moves the cursor in the reverse (REV) direc-
tion from right to left.
3.
RESULTS switch
Press the up arrow to toggle the selected bit
(blinking digit) between “1” and “0”.
4.
CATEGORY and RESULTS switches
Repeat Steps 2 and 3 until the desired loop
code is complete. Move to the end of the
programmed loop code.