6-12
SECTION 6
PRINTER
OPERATION
When bit errors are not detected, BIT ERR and
ERR SEC results remain at zero and SYNC SEC
indicates the number of seconds the synchronized
pattern was received and monitored for errors. Each
synchronized pattern is monitored for 175 seconds
during each cycle of the MULTIPAT test.
The BIT ERR result equals the sum of the five
MULTIPAT test pattern bit errors. The ASYN E
SEC result equals the sum of the five MULTIPAT
test pattern errored seconds. If pattern synchroniza-
tion is lost, SYNC SEC results are not counted.
SMART NIU Results Printout
(Enhanced ESF Option only)
The Smart NIU results printout lists the statistics
retrieved from the NIU/Performance Monitor at the
end of a standard results printout. A complete SMART
NIU results printout includes up to eight days of T1
circuit performance statistics as retrieved from the
NIU/Performance Monitor. These results include
statistics for the current hour (CURRENT HOUR),
each of the previous 23 hours (HISTORY HOUR 01
through HISTORY HOUR 23), the current day (CUR-
RENT DAY), and the previous week (HISTORY
DAY 01 through HISTORY DAY 07) as shown in
Figure 6-4.