SECTION 3
3-49
INSTRUMENT
DESCRIPTION
The far-end PRM results are available when the
ESF operating mode is selected and the AUX
DATALINK function PRM RCVR is ON. The far-
end PRM results are also available in the AUTO
LLB and T1 LLB modes.
In the SMARTNIU mode, the NIU/Performance
Monitor stored statistics can be retrieved, but they
can not be displayed in the RESULTS display. Only
the Performance Indication Ratios are displayed as
percentage values representing the overall perfor-
mance of the circuit in each direction.
SMARTNIU
PIR
RESULTS
AZ
ZA
100
94
<91
97
The retrieved data is only available as a Smart NIU
Results printout. The T1 circuit is monitored in both
directions, and the results are stored as either AZ (CO
to NIU) or ZA (Customer to NIU). The statistics are
recorded and identified as follows:
CVL
— Line Coding Violations is a count of
bipolar violations that are not part of a B8ZS
sequence.
ESL
— Line Errored Seconds is a count of
seconds in which at least one CVL has occurred.
MODE
PATTERN
CATEGORY
RESULTS
MODE
CATG
PATT