STEP1.
On the Desktop select Start/Settings/Control Panel. Select the System icon when the
Manager window opens.
STEP2.
Select Device Manager in the Systems Properties window. In the Device Manger
window select the + next to Ports (COM & LPT) to expand.
STEP3.
Highlight TRP-C38 (COM #) to be removed, go the Action tab at the top of window
and select uninstall. A confirm Device Removal window will appear. Select OK to
proceed.
STEP4.
The TRP-C38 COM # will be removed and the Device Manager window will refresh
and display the remaining COM ports.
Once all the changes have been made move to the
Configuration
screen, select
Save
and
press
Enter
. The restart message will appear. Select “Yes”
to save changes. This is necessary to
write the settings to the server.
9. Application
The TRP-C38 allows serial devices to communicate over a LAN or Intranet network. Serial
devices are no longer limited to a physical connection to the PC COM port. They can be installed
anywhere on the LAN using TCP/IP or UDP/IP communications. This will also allow traditional
PC COM ports access to a serial device anywhere on the LAN network.
9-1 Direct IP Mod
e
Direct IP connections allow applications using TCP/IP or UDP/IP network socket programs to
communicate with the asynchronous serial port on the TRP-C38. In this type of application the
TRP-C38 is configured to TCP or UDP server. The socket program running on the PC
establishes a communication connection with the TRP-C38. The raw data is sent directly to and
from the serial port
.
*RS422/485 interface (option)