serial server via the Console Mode serial port (Port 1 on TRP-C38), displaying
the Server Properties screen and allowing configuration of the server and its
ports.
• Upgrade – When this mode is selected and the server is updated, firmware can be uploaded
into the serial server via the Console Mode serial port or a virtual COM port
appeared to the number of the Console Mode serial port.
• Default – When this mode is selected and the server is updated, it will revert the server to
its default configuration.
• RS-232 – When this mode is selected and the server is updated, the selected serial port
will become a RS-232 serial port on the server.
• RS-422 – No support.
• RS-485 – No support.
Connection At
When the Connection Mode field is set to Client or Client (no heartbeat), this field becomes
active, allowing the TRP-C38 (acting as a client) to connect to the server either on Power up or
on Data Arrival (first character arriving).
Maximum Connection
This field allows the user to configure the Serial Server to have up to eight TCP connections.
Remote IP Address
This is a security feature that is activated when the IP address of the desired client is
programmed into the remote IP Address setting of the menu. This tells the TRP-C38 to
communicate with only the listed IP address and to filter out all other requests for connection.
The TRP-C38 is setup in the menu as a TCP or UDP server to us this feature.
The default setting is 255.255.255.255. It is recommended not to change this setting until the
application has been tested and is communicating properly. At that point the address filtering
feature of the TRP-C38 can be activated.
Update/Save
Server properties must be updated separately for each serial port. Updating varies slightly
depending on which of the four configuration user interfaces are used.
Updating the Server Properties in Manager Software
From the Server Properties screen, click the Update button to store the configuration settings for