ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ [email protected] ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
6
When all of the DIP switches are switched back to the OFF position, the TRP-C38 will enter Data
Mode (RS-232, RS-422 or RS-485).
2-7. DB9 Pin Configuration
Pin RS-232
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
3. Default Settings
Model Number: TRP-C38
Password: Blank
DHCP: Disable
IP address: 192.168.1.1
Netmask: 255.255.255.0
Gateway : 192.168.1.254
Version & Date: Current firmware version number and date
Serial port: 2
Baud rate: 9600
Data/Stop bits: 8-1
Parity: None
Flow control: None
Protocol: TCP
Serial timeout: 0 seconds
TCP alive timeout: 0 minutes
Connection mode: Server
Delimiter HEX 1: 00
Delimiter HEX 2: 00
Force transmit: 0 ms
Serial port mode: Console
Maximum connection: 1
Remote IP address: 255.255.255.255